qaafPakistan calculators

Electricity Unit Consumption Calculator

Adds up the units each appliance uses in a month (watts x hours x days ÷ 1,000) and estimates the bill at the current NEPRA tariff, with adjustments and taxes.بجلی کے یونٹ
ApplianceQtyWattsHrs/day

Watts are typical figures. Check the rating plate on your appliance and change them if yours differ. For fridges and ACs, hours means hours the compressor actually runs.

days
UPS losses during load shedding

Charging the batteries back up costs more units than the UPS supplies.

W
%
Bill settings
Consumer type
kW

Printed on your bill. Used for fixed charges.

Monthly electricity use30 days
Units per month
407.0kWh

You are 7 units over the 400-unit slab. Cutting that many units would drop every unit to the lower rate.

Units per day13.57
Cost of electricity 407 × 38.95Rs 15,853
Fixed chargesRs 1,500
Adjustments and surchargeRs 2,364
Duty and taxesRs 3,846
Estimated bill 407 units, unprotectedRs 23,562
ApplianceUnitsShareCost
Inverter AC 1.5 ton180.044%Rs 10,421
Ceiling fan × 4115.228%Rs 6,669
Refrigerator45.011%Rs 2,605
Water motor 1 hp22.56%Rs 1,303
LED bulb × 817.34%Rs 1,000
Iron15.04%Rs 868
LED TV12.03%Rs 695

Cost per appliance uses the bill's average of Rs 57.89 per unit.

One unit of electricity is one kilowatt-hour: 1,000 watts running for one hour. To find the units an appliance uses in a month, multiply its watts by the hours it runs each day and the days in the month, then divide by 1,000. A 1.5 ton inverter AC averaging 1,000 W for 8 hours a day uses 1,000 x 8 x 30 ÷ 1,000 = 240 units a month.

Pick your appliances above, set how many you have and how long they run, and the calculator adds up the units and estimates the bill from them. The watts are typical figures, so change them to match the rating plate on your own appliances.

How to calculate units of electricity consumed

The formula is the same for every appliance:

Units per month = watts x number of appliances x hours a day x days ÷ 1,000

  • A ceiling fan of 80 W running 12 hours a day for 30 days: 80 x 12 x 30 ÷ 1,000 = 28.8 units.
  • Eight 12 W LED bulbs for 6 hours a day: 12 x 8 x 6 x 30 ÷ 1,000 = 17.3 units.
  • A 1,000 W iron used half an hour a day: 1,000 x 0.5 x 30 ÷ 1,000 = 15 units.

If a label shows amps instead of watts, multiply the amps by 230 volts to get watts. A 5 amp load is about 1,150 W. Units on your bill are the same as kWh, so a "kWh to unit" conversion is one to one.

Typical wattage of home appliances in Pakistan

These are the starting figures in the calculator. Real models vary, so the rating plate on your appliance is the better guide.

ApplianceWattsHours a dayUnits a dayUnits in 30 days
Ceiling fan80120.9628.8
DC inverter ceiling fan35120.4212.6
Pedestal fan6080.4814.4
LED bulb1260.072.2
LED tube light2060.123.6
Energy saver (CFL)2560.154.5
Refrigerator150101.5045.0
Inverter refrigerator100101.0030.0
Deep freezer200122.4072.0
Inverter AC 1 ton70085.60168.0
Inverter AC 1.5 ton1,00088.00240.0
Inverter AC 2 ton1,400811.20336.0
Non-inverter AC 1 ton1,20089.60288.0
Non-inverter AC 1.5 ton1,800814.40432.0
Air cooler150101.5045.0
LED TV8050.4012.0
Laptop5060.309.0
Desktop computer15050.7522.5
Wi-Fi router10240.247.2
Mobile charger1030.030.9
Water motor 1 hp75010.7522.5
Water motor 0.5 hp37510.3811.3
Iron1,0000.500.5015.0
Washing machine (twin tub)40010.4012.0
Microwave oven1,2000.250.309.0
Electric kettle1,5000.200.309.0
Electric geyser2,00024.00120.0
Electric room heater1,00044.00120.0
Water dispenser100101.0030.0

For a refrigerator, freezer or AC the watts shown are while the compressor runs, and the hours are the hours it actually runs, not the hours it is switched on. A fridge compressor typically runs 8 to 12 hours out of 24.

Inverter AC power consumption

One ton of cooling is 12,000 BTU per hour, about 3.5 kW of heat removed. A fixed speed (non-inverter) AC with a typical efficiency ratio of 3 draws about 1.2 kW per ton while the compressor runs: roughly 1,200 W for 1 ton and 1,800 W for 1.5 ton.

An inverter AC slows its compressor once the room is cool, so its average draw is much lower. A study of Pakistan's cooling needs published in 2022 quotes K-Electric data of about 12 units a day for an average 1.5 ton inverter AC. That matches about 1,000 W over 12 hours, which is the figure we use.

AC, 8 hours a day for 30 days Watts Units a month
Inverter 1 ton 700 168
Inverter 1.5 ton 1,000 240
Non-inverter 1.5 ton 1,800 432

On a very hot afternoon, or with the thermostat set at 18°C, an inverter AC runs close to full power and uses more. Setting it at 26°C keeps it in its low power range for longer.

Worked example: a summer month in Lahore

This is the example loaded in the calculator: 4 ceiling fans for 12 hours, 8 LED bulbs for 6 hours, a fridge, a 1.5 ton inverter AC for 6 hours, a TV, a 1 hp water motor for an hour and an iron for half an hour, over 30 days.

Appliance Units a month
Inverter AC 1.5 ton 180.0
4 ceiling fans 115.2
Refrigerator 45.0
Water motor 22.5
8 LED bulbs 17.3
Iron 15.0
LED TV 12.0
Total 407

At September 2026 rates an unprotected 3 kW home using 407 units pays about Rs 23,562, because every unit is charged at the 401 to 500 slab rate of Rs 38.95. At 399 units the bill would be about Rs 21,590. Ironing for 15 minutes a day instead of 30 saves 7.5 units and almost Rs 2,000. Watch the slab limits at 200, 300, 400 and 500 units: the calculator warns you when you are just over one.

UPS and inverter losses

A home UPS does not make electricity. It stores it in batteries and gives back less than it took. Lead-acid batteries, the charger and the inverter together commonly lose 25 to 40% of the energy that passes through them.

If a UPS runs 300 W of fans and lights for 3 hours a day during load shedding at 70% efficiency, recharging it costs about 11.6 extra units a month. Tick the UPS option to add this. A solar system with batteries has the same kind of loss, which the solar system calculator allows for.

The bill estimate uses the NEPRA uniform tariff, the current fuel and quarterly adjustments, the debt service surcharge, electricity duty and 18% GST, the same way as our electricity bill calculator. Your meter is the final word: compare the total with the units on your bill and adjust the hours until they match.

Electricity usage questions

How many units does a 1 ton inverter AC use in an hour?

About 0.7 units an hour on average once the room has cooled, and up to about 1.2 units an hour when it runs flat out on a very hot day. Over 8 hours a day for 30 days that is roughly 168 units. A 1 ton non-inverter AC uses about 1.2 units for every hour its compressor runs.

How many units does a fan use in a month?

A normal 80 W ceiling fan running 12 hours a day uses 28.8 units in 30 days. Four such fans use about 115 units. A DC inverter fan of about 35 W uses 12.6 units for the same hours, less than half, which is why they pay back quickly in homes near a slab limit.

How do I convert watts to units?

Multiply watts by hours and divide by 1,000. A 100 W appliance running for 10 hours uses 100 x 10 ÷ 1,000 = 1 unit. One unit on your bill is one kilowatt-hour (kWh), so 1 kWh equals 1 unit.

How many units does a fridge use?

A typical fridge uses about 1 to 1.5 units a day, which is 30 to 45 units a month. Its compressor draws around 100 to 150 W but switches on and off, running about 8 to 12 hours out of 24. Older fridges, and fridges in hot kitchens, use more. An inverter fridge usually uses less.

How many units does an electric geyser use?

A 2,000 W electric geyser uses 2 units for every hour its element is on. Two hours a day adds 120 units a month, which is enough to push many homes into a higher slab. A timer so the element runs only before you need hot water keeps this down.

Related tools

Sources: NEPRA uniform domestic tariff, S.R.O. 279(I)/2026, with current adjustments from our electricity data; CLASP, Pakistan's Cooling Needs Assessment (September 2022) for inverter AC use and air conditioner efficiency; appliance wattages are typical rating plate figures and should be checked against your own appliances.

Last reviewed 29 September 2026. Results are estimates; official notices always take precedence.